The quotient end-tidal/inspired concentration of sevoflurane in a low-flow system
Related Experiment Video
Updated: Sep 30, 2026

In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
Published on: October 23, 2018
Anders Johansson1, Dag Lundberg, Hans Henrik Luttropp
1Department of Anesthesiology and Intensive Care, University Hospital of Lund, 221 85 Lund, Sweden.
Study Objective:
To investigate the effect of two different fresh gas flows on inspired and end-tidal sevoflurane concentration for a given vaporizer setting in a low-flow anesthesia system.
Design:
Prospective clinical study.
Setting:
Department of Anesthesiology of a university teaching hospital.
Patients:
56 ASA physical status I and II patients without systemic diseases, having elective surgery with an expected anesthesia time of at least 120 minutes.
Interventions:
Patients were randomly assigned to receive either 1.0 or 2.0 L/min fresh gas flow with the vaporizer setting fixed at 2% sevoflurane. The inspired (In), end-tidal (Et), and Et/In ratio sevoflurane concentrations were estimated.
Measurements And Main Results:
After 120 minutes of sevoflurane anesthesia the inspired and end-tidal sevoflurane concentration were 1.45 +/- 0.10% versus 1.28 +/- 0.12% (p < 0.001) in the 1.0 L/min group and 1.64 +/- 0.08% versus 1.46 +/- 0.11% (p < 0.001) in the 2.0 L/min group. The ratio end-tidal and inspired concentrations/vaporizer setting was 0.64 +/- 0.06 and 0.73 +/- 0.05 in the 1.0 L/min group versus 0.73 +/- 0.05 and 0.82 +/- 0.04 in the 2.0 L/min group. For the ratio inspired and end-tidal/vaporizer setting there were significant difference between the groups (p < 0.001). The estimated ratio end-tidal/inspired was 0.88 +/- 0.04 in the 1.0 L/min group versus 0.89 +/- 0.04 in the 2.0 L/min group (ns).
Conclusion:
After 120 minutes of sevoflurane anesthesia at a vaporizer setting of 2% there is a significant difference between fresh gas flow of 1.0 and 2.0 L/min for inspired and end-tidal concentrations, but not for the ratio end-tidal/inspired.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Respiratory Volumes and Capacities