Related Experiment Video
Updated: Aug 5, 2026

Investigations on the Ga(III) Complex of EOB-DTPA and Its 68Ga Radiolabeled Analogue
Published on: August 17, 2016
A class of asymmetrical nitrido 99mTc heterocomplexes as heart imaging agents with improved biological properties
A Boschi1, C Bolzati, L Uccelli
1Laboratory of Nuclear Medicine, Department of Clinical & Experimental Medicine, University of Ferrara, Via L. Borsari, 46, 44100 Ferrara, Italy.
Abstract:
Asymmetrical heterocomplexes containing a terminal technetium-nitrogen multiple bond coordinated to one diphosphine ligand (PNP) and one dithiocarbamate ligand (DBODC), were obtained through a simple two-step procedure under controlled conditions. The resulting complexes [99mTc(N)(PNP)(DBODC)]+ are monocationic, and possess a distorted square-pyramidal geometry where the Tc triple bond N multiple bond occupies an apical position and the diphosphine and dithiocarbamate ligands span the residual four coordination positions on the basal plane through the two phosphorus atoms and the two sulfur atoms, respectively. Biodistribution data in rats demonstrated that these complexes were rapidly extracted by the myocardium, and retained in this region for a prolonged time. After a few minutes post-injection, lung uptake became negligible, and liver washout was extremely rapid and quantitative. Analysis of heart/liver uptake ratios for these complexes revealed that their values increased exponentially in time, and after 60 min post-injection liver activity was almost completely eliminated into the intestine. Comparison with heart/liver ratios determined for 99mTc sestamibi and 99mTc tetrfosmin showed that values for these latter compounds were approximately 10 times lower than those measured for [99mTc(N)(PNP)(DBODC)]+ complexes at 60 min post-injection. In conclusion, the monocationic tracers [99mTc(N)(PNP)(DBODC)]+ exhibit high myocardial uptake in rats and dramatically high heart/lung and heart/liver ratios, suggesting that this novel class of perfusion agents could be conveniently employed to obtain heart images with superior imaging quality.
Related Concept Videos
Magnetic Resonance Imaging
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT

