Concurrent collection of in-line filtered platelets and red blood cells by apheresis
1Institute for Transfusion Medicine, Universitätsklinikum Essen, Hufelandstr. 55, 45122 Essen, Germany. rainer.moog@uni-essen.de
Multicomponent apheresis procedures offer the possibility to collect standardized blood components as compared to whole blood donations. A new program for the concurrent collection of platelets (PLTs) and red blood cells (RBCs) was evaluated in a prospective study. Apheresis donors ( n=18) underwent concurrent collection of PLTs and RBCs using the Haemonetics MCS+ blood cell separator. Aliquots of PLTs and RBCs were collected during five to six passes of the discontinuous flow procedure. The platelet product was in-line filtered during the last pass of the separation procedure. After collection, saline-adenine-glucose-mannitol (SAGM) preservative solution was automatically added to the RBCs. Thereafter, the RBCs were in-line leukodepleted by gravity filtration at room temperature. The PLTs and RBCs were subsequently stored at 22+/-2 degrees C for 5 days and 4+/-2 degrees C for 35 days, respectively. The following in vitro parameters were evaluated over the storage periods: blood cell counts, glucose, lactate, lactate dehydrogenase, pH, plasma hemoglobin, and potassium. Two ready-to-use blood components from one donor were collected in an average procedure time of 86+/-10 min; 2.47+/-0.74 x 10(11) PLTs were collected in a product volume of 232+/-43 ml. The RBC volume averaged 280+/-20 ml and the hemoglobin content was 56.8+/-2.4 g per unit. The leukocyte contamination of the platelet product was 0.44+/-0.56 x 10(5) and the residual leukocyte content of the RBC product was 0.28+/-0.02 x 10(5). Storage data showed no relevant drop in pH. Day 35 results of the RBC products showed that all of the units had less than 0.8% hemolysis. Standardized PLT and RBC products of good quality can be concurrently collected with the MCS+ blood cell separator. In vitro testing of the products collected and stored for 5 and 35 days, respectively, met the Council of Europe criteria for leukodepleted blood products.
Multicomponent apheresis procedures offer the possibility to collect standardized blood components as compared to whole blood donations. A new program for the concurrent collection of platelets (PLTs) and red blood cells (RBCs) was evaluated in a prospective study. Apheresis donors ( n=18) underwent concurrent collection of PLTs and RBCs using the Haemonetics MCS+ blood cell separator. Aliquots of PLTs and RBCs were collected during five to six passes of the discontinuous flow procedure. The platelet product was in-line filtered during the last pass of the separation procedure. After collection, saline-adenine-glucose-mannitol (SAGM) preservative solution was automatically added to the RBCs. Thereafter, the RBCs were in-line leukodepleted by gravity filtration at room temperature. The PLTs and RBCs were subsequently stored at 22+/-2 degrees C for 5 days and 4+/-2 degrees C for 35 days, respectively. The following in vitro parameters were evaluated over the storage periods: blood cell counts, glucose, lactate, lactate dehydrogenase, pH, plasma hemoglobin, and potassium. Two ready-to-use blood components from one donor were collected in an average procedure time of 86+/-10 min; 2.47+/-0.74 x 10(11) PLTs were collected in a product volume of 232+/-43 ml. The RBC volume averaged 280+/-20 ml and the hemoglobin content was 56.8+/-2.4 g per unit. The leukocyte contamination of the platelet product was 0.44+/-0.56 x 10(5) and the residual leukocyte content of the RBC product was 0.28+/-0.02 x 10(5). Storage data showed no relevant drop in pH. Day 35 results of the RBC products showed that all of the units had less than 0.8% hemolysis. Standardized PLT and RBC products of good quality can be concurrently collected with the MCS+ blood cell separator. In vitro testing of the products collected and stored for 5 and 35 days, respectively, met the Council of Europe criteria for leukodepleted blood products.