The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Translaryngeal tracheostomy in acute respiratory distress syndrome patients
Annalisa Benini1, Nicola Rossi, Paolo Maisano
1Department of Anesthesia and Intensive Care, S. Gerardo Hospital, Monza, Italy.
Objective:
To prevent gas exchange deterioration during translaryngeal tracheostomy (TLT) in patients with acute respiratory distress syndrome (ARDS) ventilation is maintained through a small diameter endotracheal tube (ETT; 4.0 mm i.d.) advanced beyond the tracheostoma. We report on the feasibility of uninterrupted ventilation delivered through a high-resistance ETT in ARDS patients, and relevant ventilatory adjustments and monitoring.
Design And Setting:
Prospective, observational clinical study in an eight-bed intensive care unit of a university hospital.
Patients:
Eight consecutive ARDS patients scheduled for tracheostomy.
Interventions:
During TLT volume control ventilation was maintained through the 4.0-mm i.d. ETT. Tidal volume, respiratory rate, and inspiratory to expiratory ratio were kept constant. Fractional inspiratory oxygen was 1. Positive end expiratory pressure (PEEP) set on the ventilator (PEEP(vent)) was reduced to maintain total PEEP (PEEP(tot)) at baseline level according to the measured intrinsic PEEP (auto-PEEP).
Measurements And Main Results:
Data were collected before tracheostomy and while on mechanical ventilation with the 4.0-mm i.d. ETT. Neither PaCO(2) nor PaO(2) changed significantly (54.5+/-10.0 vs. 56.4+/-7.0 and 137+/-69 vs. 140+/-59 mmHg, respectively). Auto-PEEP increased from 0.6+/-1.1 to 9.8+/-6.5 cmH(2)O during ventilation with the 4.0-mm i.d. ETT. By decreasing PEEP(vent) we obtained a stable PEEP(tot) (11.4+/-4.3 vs. 11.8+/-4.3 cmH(2)O), and end-inspiratory occlusion pressure (26.7+/-7.4 vs. 28.0+/-6.6 cmH(2)O). Peak inspiratory pressure rose from 33.8+/-8.1 to 77.8+/-12.7 cmH(2)O.
Conclusions:
The high-resistance ETT allows ventilatory assistance during the whole TLT procedure. Assessment of stability in plateau pressure and PEEP(tot) by end-inspiratory and end-expiratory occlusions prevent hyperinflation and possibly barotrauma.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...