Analysis of estrogenic contaminants in river water using liquid chromatography coupled to ion trap based mass
Tom Benijts1, Riet Dams, Wolfgang Günther
1Laboratorium voor Toxicologie, Universiteit Gent, Harelbekestraat 72, B-9000 Gent, Belgium.
Abstract:
A precise and reliable method, using liquid chromatography combined with ion trap based mass spectrometry, for the determination of three endogenous estrogens, namely, estrone, estradiol, and estriol, and two synthetic estrogens, ethinyl estradiol and diethylstilbestrol, in environmental water samples was developed. Optimization of the parameter settings of the ion source and mass analyzer as well as evaluation of solvent composition were carried out by continuous introduction of standards through a syringe pump. In negative ion mode the electrospray ionization source gave acceptable results. The optimum solvent used consisted of water/acetonitrile, with no volatile bases or buffers added. A simple, off-line, manual solid-phase extraction method was developed for sample preparation of environmental water samples. Recoveries were over 86% for all compounds. The method was validated and found to be linear, selective, and robust. For analysis of a 50-mL sample, the limit of detection (LOD) ranged from 3.2 to 10.6 ng/L for all compounds, and the limit of quantitation (LOQ) from 10.6 to 35.0 ng/L. Within-day (n = 5) and total (n = 5) reproducibility were investigated at three different concentration levels and ranged from 6.2 to 9.5% and 9.4 to 12.1%, respectively. Finally, the method was applied to real-world samples.
More Related Videos
09:49Use of a Battery of Chemical and Ecotoxicological Methods for the Assessment of the Efficacy of Wastewater Treatment Processes to Remove Estrogenic Potency
Published on: September 11, 2016
10:44Clean Sampling and Analysis of River and Estuarine Waters for Trace Metal Studies
Published on: July 1, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Ion-Exchange Chromatography
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Elution Process