Reevaluation of the needle method for measuring interstitial fluid pressure
Related Experiment Video
Updated: Aug 22, 2026

A Reversible, Non-invasive Method for Airway Resistance Measurements and Bronchoalveolar Lavage Fluid Sampling in Mice
Published on: April 14, 2010
Abstract:
Inserting a needle into subcutaneous spaces should allow a subatmospheric pressure to be measured if interstitial fluid pressure is truly negative as measured by the capsule and wick techniques. Previous needle measurements of interstitial fluid pressure have produced a positive value, but in most instances fluid has been injected into the tissues prior to recording of pressure. Therefore, we measured subcutaneous needle pressure in anesthetized dogs without fluid injection into the tissues. Approximately 30 min are required for an equilibrium pressure after insertion of the needle. The mean 30-min pressure was 4.6 +/- 0.5 (SE) mmHg (n equals 41). With observable edema, interstitial fluid pressures as measured with the needle were always positive. However, the needle method for continuous recording of pressure lacks rapid sensitivity to changes in tissue fluid pressures. In order to develop a needle method that would follow changes in interstitial fluid pressure, 0.5-1 mul of saline was injected into or withdrawn from the tissue. With this method, pressure plateaued in 10-20 min. This plateau pressure increased with tissue hydration and decreased with dehydration.
More Related Videos
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...