Intraoperative confirmation of ulnar collateral blood flow during radial artery harvesting using the "squirt test"

Inderpaul Birdi1, Andrew J Ritchie

  • 1Papworth Hospital, Papworth Everard, Cambridge, United Kingdom. inderuk@hotmail.com

Hand ischemia is a major concern after radial artery harvesting for coronary revascularization. Although a number of preoperative tests have been described to assess the adequacy of ulnar collateral blood flow, many of them are subjective and unreliable. In addition, the presence of arterial connections between the radial and ulnar systems in the elbow and forearm and variability in forearm angiology imply that assessment of alternative blood supply to the hand can only be made once collateral branches of the radial artery have been divided. We describe a technique for intraoperative assessment of ulnar collateral blood flow after mobilization and division of collateral branches of the radial artery.

Related Concept Videos

Assessment of radial pulse01:11

Assessment of radial pulse

Assessment of Radial Pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse01:25

Assessment of apical radial pulse

Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Arteries of the Upper Limbs01:12

Arteries of the Upper Limbs

The subclavian artery transitions into the axillary artery as it exits the chest and enters the axillary region. This artery is critical for supplying blood to the shoulder area, including the head of the humerus, through the humeral circumflex arteries. As the vessel continues into the upper arm or brachium, it becomes the brachial artery. This artery plays a key role in vascularizing the brachial region and bifurcates at the elbow into several branches. These branches include the deep...
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: