Related Experiment Video
Updated: Aug 7, 2026

Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Optimization of transthoracic ventricular defibrillation-biphasic and triphasic shocks, waveform rounding, and
Bakhtiar J Kidwai1, Allister McIntyre, John Anderson
1Regional Medical Cardiology Centre, Royal Victoria Hospital, Belfast, Ireland.
Abstract:
The aim of this study is to optimize the truncated exponential waveform for transthoracic ventricular defibrillation. Discharge of a capacitor gives a fast-rising waveform with a spike; rounding of the waveform slows the rate of rise and removes the spike. Defibrillation thresholds for electrically induced VF were determined for rounded and conventional biphasic and triphasic waveforms (apex-anterior paddles; 130 microF capacitor; 3-10 ms phase duration), and for the Lown waveform in 29 anesthetized pigs. Rounding of the leading edge of the biphasic waveform reduced the threshold voltage and current for defibrillation at 3 + 3 ms and 6 + 6 ms phase duration, relative to the conventional unrounded biphasic or the Lown waveforms. The threshold delivered energy was lower for rounded truncated exponential biphasic shocks at 3 + 3 ms (55.3 +/- 2.5 J) than at 6 + 6 ms (67.6 +/- 2.9 J; reduction 15.9 +/- 3.8%; P <.001; n = 29) phase duration. Triphasic shocks (total duration 6-12 ms) showed no advantages over biphasic shocks in this model. The rounded waveform (6 + 6 ms phase duration) had a reduced delivered energy at threshold (9%) with transthoracic shock delivery synchronized to peak (71.1 +/- 4.2 J) or trough (71.5 +/- 4.9 J) of the high amplitude body surface electrocardiogram signal in ventricular fibrillation, compared with unsynchronized shocks (78.7 +/- 4.7 J; P <.05). In this study a biphasic, rounded waveform of total duration 6 or 12 ms, was optimal for the correction of electrically-induced ventricular fibrillation. Synchronization to the peak or trough of the high amplitude electrocardiogram signal gave a further reduction in the energy to defibrillate.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
08:43Advanced Cardiac Rhythm Management by Applying Optogenetic Multi-Site Photostimulation in Murine Hearts
Published on: August 26, 2021
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias VI: Management of Dysrhythmias
Cardiopulmonary Resuscitation III: AED Use
Cardiopulmonary Resuscitation IV: Pharmacological Management
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias