Related Concept Videos

Amides to Amines: LiAlH4 Reduction01:20

Amides to Amines: LiAlH4 Reduction

Amide reduction with strong reducing agents like lithium aluminum hydride proceeds through a nucleophilic acyl substitution to form amines. Primary, secondary, and tertiary amides yield primary, secondary, and tertiary amines, respectively.
Amide reduction requires two equivalents of the reducing agent, acting as a source of hydride ions. As shown in the figure, the reaction is initiated with a nucleophilic attack by the hydride ion at the carbonyl carbon to form a tetrahedral intermediate.
meta-Directing Deactivators: –NO2, –CN, –CHO, –⁠CO2R, –COR, –CO2H01:13

meta-Directing Deactivators: –NO2, –CN, –CHO, –⁠CO2R, –COR, –CO2H

All meta-directing substituents are deactivating groups. These substituents withdraw electrons from the aromatic ring, making the ring less reactive toward electrophilic substitution. For example, the nitration of nitrobenzene is 100,000 times slower than that of benzene because of the deactivating effect of the nitro group. The first step in an electrophilic aromatic substitution is the addition of an electrophile to form a resonance-stabilized carbocation. The energy diagrams for the...
¹³C NMR: ¹H–¹³C Decoupling01:04

¹³C NMR: ¹H–¹³C Decoupling

The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and refractory oxide ion...
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Carbon-dioxide Fixation01:28

Carbon-dioxide Fixation

Carbon dioxide fixation in prokaryotes enables the assimilation of inorganic carbon into organic molecules, supporting biosynthetic pathways, sustaining ecosystems, and contributing to the global carbon cycle. It also has industrial applications in carbon capture and bioproduct synthesis. Autotrophic organisms rely on this process to utilize CO₂ as a carbon source in diverse environments.The Calvin CycleThe Calvin cycle is the most widespread carbon fixation mechanism, primarily used by...