Increasing respiratory rate to improve CO2 clearance during mechanical ventilation is not a panacea in acute
Antoine Vieillard-Baron1, Sebastien Prin, Roch Augarde
1Medical Intensive Care Unit, University Hospital Ambroise Paré, Assistance Publique Hôpitaux de Paris, Boulogne Cedex, France.
Background:
Increasing respiratory rate has recently been proposed to improve CO2 clearance in patients with acute respiratory failure who are receiving mechanical ventilation. However, the efficacy of this strategy may be limited by deadspace ventilation, and it might induce adverse hemodynamic effects related to dynamic hyperinflation.
Setting:
An intensive care unit of a university hospital.
Patients:
We studied 14 patients with acute respiratory failure during the adjustment of ventilator settings on the first day of mechanical ventilation in volume-controlled mode.
Measurements:
After determining the positive end-expiratory pressure that suppresses any intrinsic positive end-expiratory pressure at a respiratory rate of 15 breaths/min, we compared blood gas analysis, respiratory measurements, and Doppler evaluation of right ventricular systolic function by using two different respiratory strategies with the same airway pressure limitation (plateau pressure, < or =25 cm H2O), a low-rate conventional respiratory strategy with a respiratory rate of 15 breaths/min, and a high-rate strategy with a respiratory rate of 30 breaths/min.
Results:
Compared with the low-rate strategy, the high-rate strategy neither significantly reduced PaCO2 (47 +/- 8 vs. 51 +/- 7 mm Hg with the low-rate strategy) nor significantly improved PaO2 (99 +/- 40 vs. 95 +/- 35 mm Hg with the low-rate strategy). It significantly increased alveolar deadspace to tidal volume ratio (21% +/- 8%, vs. 14% +/- 6% with the low-rate strategy) and produced dynamic hyperinflation, resulting in a substantial intrinsic positive end-expiratory pressure (6.4 +/- 2.7 cm H2O). Right ventricular outflow impedance was increased, resulting in a significant drop in the cardiac index (2.9 +/- 0.6 vs. 3.3 +/- 0.7 L/min/m with the low-rate strategy).
Conclusion:
We conclude that a high respiratory rate strategy during mechanical ventilation in patients with acute respiratory failure did not improve CO2 clearance, produced dynamic hyperinflation, and impaired right ventricular ejection.
More Related Videos
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome (ARDS)
Published on: April 7, 2021
08:223D Cine Magnetic Resonance Imaging of Respiratory Motion in Mechanically Ventilated Mice and Rats
Published on: September 19, 2025
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-III
Acute Respiratory Failure-IV
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...