New chromatographic method for separation and determination of denatured alphaS1-, alphaS2-, beta- and kappa-caseins

Emilia Bramanti1, Chandra Sortino, Giorgio Raspi

  • 1National Council of Research, CNR, Istituto per i Processi Chimico-Fisici, Pisa, Italy. emilia@icas.pi.cnr.it

Separation and determination of denatured alpha-, beta- and kappa-caseins by hydrophobic interaction chromatography (HIC) was improved by using a TSK-Gel Ether-5PW column (Tosoh Biosep). The method, already proposed and performed by a TSK-Gel Phenyl-5PW column (Tosoh Biosep), is based on fast and easy solubilization of commercial and real samples by 4.0 M guanidine thiocyanate and HIC analysis in the presence of 8.0 M urea in the mobile phase. Employment of the less hydrophobic ether phase had the main advantage of separating casein fractions in less than 22 min and, additionally, of separating a-casein in kappaS1- and alphaS2 -casein fractions. The method has been validated by the analysis of reference skim milk powder (BCR-063R) certified for total nitrogen content. A linear relationship between the concentration of casein and peak area (UV absorbance detector at 280 nm) has been obtained over the concentration range of 0.5-40 microM. The detection limit for alpha-, beta- and kappa-caseins ranged between 0.33 and 0.65 microM. The precision of the method was evaluated, the RSDs for alphaS1-, alphaS2-, beta- and kappa-casein determination ranging between 2.3 and 5.5% for standard solutions and between 4.4 and 6.2% for real sample solutions. The mean value of casein content found in eight aliquots of BCR-063R calculated with respect to the total protein content (estimated on the basis of certified total nitrogen content) was 78.3 +/- 6.1%. Results of linear fitting of standard additions data of alphaS1-, alphaS2-, beta- and kappa-caseins to BCR-063R were compared with linear fitting of alphaS1-, alphaS2-, beta- and kappa-casein calibration data. The method was applied to commercial caseins and to 30 real, raw samples. A statistical comparison was performed between results on quantitation of alpha-, beta- and kappa-caseins obtained by TSK-Gel Ether-5PW and TSK-Gel Phenyl-5PW HIC columns, showing more accurate results for chromatographic analysis performed by the ether column.

Related Concept Videos

Types Of Column Chromatography01:29

Types Of Column Chromatography

The stability and compatibility of column material with samples are crucial for efficient purification in chromatographic techniques. Various operating parameters such as pH, temperature, or solvent affect the packing of the column material, thereby determining the purification efficiency. The choice of column material also plays an essential role in deciding the operating parameters and can be modified based on the proteins that need to be purified.
Gel Filtration Chromatography
When the...
Affinity Chromatography01:03

Affinity Chromatography

Affinity chromatography is a powerful technique extensively utilized for separating and purifying specific biomolecules from complex mixtures. It capitalizes on the highly selective binding between an analyte and its counterpart, such as antibody-antigen interactions. The counterpart is immobilized on the stationary phase, forming an affinity column. The stationary phase typically consists of solid support, such as agarose or porous glass beads, immobilizing the affinity ligand. The mobile...
High-Performance Liquid Chromatography: Introduction01:11

High-Performance Liquid Chromatography: Introduction

High-performance liquid chromatography(HPLC), formerly referred to as High-pressure liquid chromatography, is a powerful technique used to separate, identify, and quantify components in complex mixtures. The term "high pressure" refers to using high pressure to push the liquid mobile phase through the tightly packed columns.
In HPLC, two phases play a critical role in the separation process:
Two-dimensional Gel Electrophoresis01:22

Two-dimensional Gel Electrophoresis

Two-dimensional gel electrophoresis is a high-resolution protein separation method first introduced by O' Farrell and Klose in 1975. This method involves protein separation by two dimensions, mass and charge, making it more accurate than one-dimensional gel electrophoresis.
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as  cells...
Chromatographic Methods: Classification01:12

Chromatographic Methods: Classification

Chromatographic techniques are classified in three ways: the classification is based on the physical state of the stationary and mobile phases, how the mobile phase and the stationary phase contact each other, or through the chemical or physical processes that isolate the components of the sample. Typically, the mobile phase is either a liquid or gas, while the stationary phase is either a solid or a liquid layer applied to a solid surface.
Chromatographic techniques are typically named by...
Size-Exclusion Chromatography01:08

Size-Exclusion Chromatography

In size-exclusion chromatography (SEC), also known as molecular-exclusion or gel-permeation chromatography, molecules are separated based on their sizes. This technique is important for separating large molecules such as polymers and biomolecules. The two classes of micron-sized stationary phases encountered in SEC are silica particles and cross-linked polymer resin beads. Both materials are porous, but their pore sizes vary significantly.
Silica particles offer advantages such as rigidity,...