Related Experiment Videos
Gadobutrol: an alternative contrast agent for digital subtraction dacryocystography
M Priebe1, A Mohr, J Brossmann
1Department of Diagnostic Radiology, Christian-Albrechts-University of Kiel, Arnold-Heller-Strasse 9, 24105 Kiel, Germany. m.priebe@t-online.de
Abstract:
We report the application of gadobutrol as a contrast medium for digital subtraction dacryocystography (DS-DCG) in patients with known allergy to iodinated contrast agent. Gadobutrol has the double gadolinium concentration (1.0 mmol/ml) of other gadolinium-based contrast agents. Quality of the DS-DCG images obtained with gadobutrol was comparable to DS-DCG images obtained with iodinated contrast medium. Radiodensity measurements using a micro-CT scanner confirmed a high radiodensity of gadobutrol which was comparable to the radiodensity of iopentol with a iodine concentration of 250 mg/ml and only approximately 20% lower than the radiodensity of iopentol with a concentration of 300 mg/l. Gadobutrol is a well-suited substitute for DS-DCG in patients with allergy to iodinated contrast agents.