Related Experiment Video
Updated: Sep 11, 2026

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Successful transcatheter retrieval of an embolized stent from the left ventricle
Hüseyin Y lmaz1, Aytül Belgi, Ibrahim Demir
1Department of Cardiology, Akdeniz University School of Medicine, Antalya, Turkey. drhy@um.turkcell.com.tr
Abstract:
Systemic embolization complicating intracoronary stenting before deployment is a rare complication; although it was not associated with any clinical sequelae, great care should be taken to prevent this possibility. We report a case of the successful retrieval of an embolized stent from the left ventricle during percutaneous transluminal coronary angioplasty of a left anterior descending coronary artery.
More Related Videos
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care