Finapres arterial pulse wave analysis with Modelflow is not a reliable non-invasive method for assessment of cardiac
Jaap J Remmen1, Wim R M Aengevaeren, Freek W A Verheugt
1Department of Geriatric Medicine, Heartcenter, Department of Cardiology, University Medical Center Nijmegen, P.O. Box 9101, 6500 HB Nijmegen, The Netherlands. jremmen@czzoger.azn.nl
Abstract:
Non-invasive continuous monitoring of cardiac output could be very useful in clinical care and in research settings, particularly in elderly subjects. We studied whether Finapres arterial pulse wave analysis with Modelflow is a reliable non-invasive method for the assessment of cardiac output in healthy elderly subjects. We compared Modelflow cardiac output (MFCO) with thermodilution cardiac output (TDCO) in 28 healthy subjects, aged 70+/-4 years (mean+/-S.D.). TDCO was measured during right-sided heart catheterization, while MFCO was calculated with Modelflow(R) software from non-invasive arterial Finapres blood pressure, which was measured simultaneously. The two methods were compared using a paired t-test, by Pearson correlation, and by Bland-Altman analysis. TDCO was 6.4+/-1.1 litres/min (mean+/-S.D.) and MFCO was 4.7+/-1.3 litres/min (P<0.001). There was no significant correlation between MFCO and TDCO (r=0.28, P=0.13). Mean difference (bias) was -1.7 litres/min (S.E.M. 0.27 litres/min), with an S.D. (precision) of 1.5 litres/min. The 95% limits of agreement were -4.6 to +1.1 litres/min. In conclusion, non-invasive MFCO values differed significantly from and showed no significant correlation with invasively determined TDCO values in the normal range. Although simple, non-invasive and patient-friendly, the Modelflow method is inaccurate for assessment of cardiac output without invasive calibration.
Related Concept Videos
Pulse
The pulse serves as a clinical indicator...
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Pulse Assessment Sites