[Intraoperative computer tomography control within the scope of maxillofacial traumatology using a mobile scanner]
Related Experiment Video
Updated: Sep 30, 2026

Digital Hybrid Model Preparation for Virtual Planning of Reconstructive Dentoalveolar Surgical Procedures
Published on: August 5, 2021
J Hoffmann1, F Dammann, D Troitzsch
1Klinik und Poliklinik für Mund-, Kiefer- und Gesichtschirurgie, Universitätsklinikum Tübingen. juergen.hoffmann@uni-tuebingen.de
Abstract:
Advances in intra-operative imaging and the development of new minimally invasive techniques are having an ever greater impact on modern surgery. Mobile CT scanners in the operating room is a new technique that permits image-guided surgery, and helps minimize postoperative complications. We report on our initial experience with intraoperative CT scanning during surgery on patients suffering lateral midface trauma. A mobile CT unit, the Tomoscan M (Philips, Utrecht, Netherlands) set up in the operating room, was evaluated in 6 patients with zygomatic bone fractures. The patients were placed on the CT scanner table, which is detachable from the gantry. The unit is powered by batteries charged from an ordinary ring mains supply via a conventional plug. The CT images obtained were of good quality in all cases. No technical problems were observed during surgery. Using repeat CT scans, the procedure also permits accurate intraoperative monitoring of the anatomical repositioning of the bone fragments, and accurate implantation. No intraoperative or early postoperative complications were observed. This new technical aid ensures highly accurate reduction of the bone fragments, and minimizes the need for reoperation. High-quality intraoperative imaging with surgical navigation increase surgical outcome, and expand the spectrum of minimally invasive surgery.
More Related Videos
05:49Reliability of Artificial Intelligence-Based Cone Beam Computed Tomography Integration with Digital Dental Images
Published on: February 23, 2024
05:54Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography