Related Experiment Video
Updated: Jul 9, 2026

Sheathless Capillary Electrophoresis–Mass Spectrometry for Metabolic Profiling of Biological Samples
Published on: October 1, 2016
Position and intensity of system (eigen) peaks in capillary zone electrophoresis
1Research Group on Polymer Analysis, Institute of Technical Chemistry, Amsterdam, The Netherlands.
Abstract:
The intensity of system (or eigen) peaks encountered in capillary zone electrophoresis (CZE) can be predicted by considering mass balances for each of the analyte constituents and each of the constituents in the background electrolyte (BGE). As a result of coherence, in each zone the proportions in which the constituent concentrations vary are fixed; they are determined by the composition of the BGE and the nature of the analyte constituent (if present) and described as eigenvectors of a transport matrix. Considering the effect of an injection, the mass balances for all constituents can be satisfied only via the intensity of each zone. This leads to an n-equations, n-unknowns problem, with the intensities as the unknowns and the mass balances as equations. The latter can be easily solved to obtain the intensities. of the zones, of analytes as well as of system peaks. In this work the approach has been applied to CZE systems with two co-ions in the BGE, and experimental results have been compared to the predictions obtained from the model. Agreement was seen to be reasonable, but the quantitative comparison often failed, probably due to experimental difficulties.
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...

