Related Experiment Video
Updated: Sep 30, 2026

Ultrasound Velocity Measurement in a Liquid Metal Electrode
Published on: August 5, 2015
Ultrasonic sensor to measure the density of a liquid or slurry during pipeline transport
Margaret S Greenwood1, Judith A Bamberger
1Pacific Northwest National Laboratory, Richland, WA 99352, USA. margaret.greenwood@pnl.gov
Abstract:
This paper describes the design and testing of a computer-controlled sensor for the real-time measurement of the density of a liquid or slurry. It is to be deployed at the US Department of Energy's Hanford Site in Richland, WA, to monitor slurry properties during radioactive waste transfers. To demonstrate the sensor performance, tests were carried out using non-radioactive waste simulants and the results will be presented. The sensor is mounted flush with the pipeline wall in a nominal 5-cm (2-in.) pipe spool piece. The design pressure is 2.8 MPa (400 psi). The probe wedge in contact with the slurry was selected to operate up to pH 14, and the probe components were radiation tested at exposures of 1 x 10(6) R. The sensor is applicable for process control of all types of liquids or slurries in pipelines or in vessels.
Related Concept Videos
Pipe Flowrate Measurement
The orifice meter is a simple,...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Pipe Flowrate Measurement: Problem Solving