Related Experiment Video
Updated: Sep 30, 2026

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Unintentional deactivation of implantable cardioverter-defibrillators in health care settings
Mary Jane Rasmussen1, Paul A Friedman, Stephen C Hammill
1Guidant Corporation, St Paul, Minn 55905, USA.
Abstract:
Patients with implanted pacemakers and defibrillators are routinely cautioned regarding exposure to environmental magnetic fields because such exposure may interfere with device function. Previous reports have confirmed interference with bingo wands, stereo speakers, and various workplace sources. In the 4 patients in this report, we document inadvertent alteration of the tachyarrhythmia detection function of implantable cardioverter-defibrillators (ICDs) that occurred in health care settings because of deliberately applied magnetic fields. Three of these patients had pectorally implanted ICDs that may have been confused with pacemakers, and 2 patients had undergone office surgical procedures at which time a magnet had been applied over the device. These events stemmed from (1) potential confusion by health care workers about the nature of the implanted device and (2) unique features in a specific manufacturer's defibrillator. We recommend the following steps to avoid such problems: (1) when device programming hardware and trained personnel are readily available, the patient's device should be interrogated and reprogrammed before and after any procedure involving electrocautery; (2) patients with ICDs should be monitored during device inactivation because they are unprotected from potentially life-threatening arrhythmias during this period; and (3) if the clinical situation does not allow device interrogation and reprogramming, the patient should be monitored electrocardiographically during magnet application and the device interrogated as soon as possible after magnet removal.
Related Concept Videos
Cardiopulmonary Resuscitation III: AED Use
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Cardiomyopathy V: Interprofessional Care
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Dysrhythmias VI: Management of Dysrhythmias
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...

