Related Experiment Video
Updated: Aug 6, 2026

07:09
In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Effects of immediate loading with threaded hydroxyapatite-coated root-form implants on single premolar replacements:
Periklis Proussaefs1, Joseph Kan, Jaime Lozada
1Graduate Program in Implant Dentistry, Loma Linda University, California 92350, USA. pProussaef@hotmail.com
The International Journal of Oral & Maxillofacial Implants
|August 17, 2002
Summary
Immediate loading of single root-form implants in the maxillary premolar area shows promising results. Peri-implant bone levels and soft tissue parameters were comparable to conventional methods.
Area of Science:
- Dental Implantology
- Prosthodontics
- Oral Surgery
Background:
- Immediate loading protocols for dental implants are gaining traction.
- Assessing the efficacy of immediate loading in the esthetic zone is crucial for patient satisfaction.
Purpose of the Study:
- To evaluate the immediate loading of single, threaded, root-form implants in the maxillary premolar region.
- To assess peri-implant bone and soft tissue parameters following immediate loading.
Main Methods:
- A prospective study involving ten human subjects.
- Immediate placement of a screw-retained temporary acrylic resin crown after implant surgery.
- Placement of a definitive metal-ceramic crown after 6 months.
Main Results:
- Mean marginal bone loss ranged from 0.58 mm at 1 month to 0.90 mm at 12 months.
- Implant mobility remained stable, with mean Periotest values around -3.3.
- Peri-implant soft tissue parameters, including probing depth and recession, showed stability.
Conclusions:
- Immediate loading of single root-form implants in the maxillary premolar area is a viable option.
- Peri-implant parameters were comparable to those observed with conventional two-stage loading protocols.
- The findings support the immediate loading protocol under the study's conditions.