Related Experiment Video
Updated: Sep 29, 2026

A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Functional versus fractional oxygen saturation readings: bias and agreement using simulated solutions and adult blood
1School of Nursing at the University of Texas Health Science Center at Houston, 77030, USA. pshiao@son1.nur.uth.tmc.edu
Abstract:
The purpose of this study was to examine the bias and agreement between functional oxygen saturation (SO2) and fractional oxyhemoglobin (HbO2) using simulated quality control (QC) solutions and adult blood. Using a hemoximeter, 5 analysts performed at least 5 tests each on QC solutions with 3 different hemoglobin (Hb) levels and on adult blood samples of various oxygen saturation levels representing venous or arterial samples. Bias and the limits of agreement were determined using the technique of Bland and Altman. Using QC solutions with low, normal, and high Hb levels, the bias for SO2 against HbO2 was 20.82 +/- 0.50 (n = 66), 19.14 +/- 0.56 (n = 81), and 19.59 +/- 0.43 (n = 79), respectively, with SO2 reading consistently higher. The correlation between SO2 and HbO2 was -0.49, -0.69, and -0.68, respectively. Using adult blood, the bias for SO2 against HbO2 was 1.29 +/- 0.48 for venous samples (n = 62) and 1.9 +/- 0.19 for fully oxygenated samples (n = 36), and the correlation between SO2 and HbO2 was 1.0 and 0.68, respectively. These findings suggest that the consistency between the measurements of SO2 and HbO2 may be dependent on hemoglobin levels and oxygenation status. Thus, caution is warranted when assuming that the measurements of SO2 and HbO2 are interchangeable.
More Related Videos
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Oxygen Transport in the Blood
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...