Related Experiment Video
Updated: Aug 12, 2026

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
Generic serial and parallel on-line direct-injection using turbulent flow liquid chromatography/tandem mass
Russell P Grant1, Cheryl Cameron, Shelley Mackenzie-McMurter
1Lilly Laboratory for Bioanalytical Research, Eli Lilly Canada Inc., 3650 Danforth Avenue, Toronto, M1N 2E8 Canada. Grant_Russell@Lilly.com
Abstract:
The development of turbulent flow chromatography (TFC) has enabled considerable growth in the utility of on-line direct-injection technologies. TFC has now become established in a large number of varied analytical environments, particularly drug discovery/pharmacokinetics, metabolite profiling, combinatorial library purification, pre-clinical and clinical GLP applications. The utility of turbulent flow technology for in-house pre-clinical and clinical quantitative applications has necessitated extensive valve-cleaning procedures, and consequently lengthy cycle-times, to effectively remove the system carry-over. In-house requirements for assay validation require carry-over less than 20% of the lowest level of quantification (LLOQ), corresponding to 0.02% carry-over for a linear calibration range incorporating 3 orders. A generic turbulent flow chromatography protocol has been developed for drug discovery that incorporates polymeric turbulent flow extraction (cyclone) with C18-based reverse-phase chromatography. Further, multiple wash steps are incorporated within the methodology to meet in-house requirements for carry-over. Selection of novel switching-valve materials based on polyarylethyl ketone (PAEK) and Hastelloy/Valcon E autosampler injection hardware has enabled us to significantly impact the cycle-time required to reduce carry-over. Consequently, optimal usage of switching valves has enabled parallel operation for a generic on-line direct-injection methodology to successfully reduce the total cycle-time. Overall reductions from 4 min per sample to 90 s per sample are shown with comparable data quality using a proprietary target molecule from 0.1-100 ng/mL. This paper describes the hardware configuration and methodologies utilized to perform generic serial and parallel on-line direct-injection using a Turboflow HTLC 2300 system.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation