Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Pulse oximeter-enhanced accuracy of capnometry in children with cyanotic heart disease
Jaap W De Vries1, Frans B Plötz, A Johannes Van Vught
1Department of Anesthesia, Intensive Care and Pain, Mesos Medical Center, PO box 8605, 3503 RP Utrecht, The Netherlands. jwdvries@mesos.nl
Objectives:
To evaluate the relationship between the arterial end-tidal partial pressure of carbon dioxide (PCO2) difference (deltapCO2) and the degree of desaturation in children with cyanotic heart disease (CHD) and to come to a more reliable estimation of the arterial carbon dioxide partial pressure (PaCO2) from the end-tidal carbon dioxide partial pressure (PET-CO2).
Design And Setting:
In part retrospective, in part prospective observational study at a university children's hospital.
Subjects And Interventions:
We retrospectively assessed the relationship between the arterial oxygen saturation as measured by means of pulse oximetry (SpO2) and the arterial to end-tidal PCO2 differences (deltaPCO2) from the records of medical or surgical interventions in 43 patients with CHD. We derived a PaCO2-PET-CO2 correction formula that was prospectively validated in 34 patients with CHD.
Measurements And Results:
In the retrospective part we found a significant correlation between SpO2 and deltaPCO2 ( r (2)=0.84, p<0.001). The regression equation (corrected PET-CO2=raw PET-CO2-0.36xSpO2+39) was used in the prospective part to calculate the corrected PET-CO2. The r (2)s for the correlations between PaCO(2) and uncorrected and corrected PET-CO2 were 0.17 ( p<0.05) and 0.94 ( p<0.001), respectively. The uncorrected PET-CO2 bias was 13.0 mmHg, the bias +/- 2SDs was -0.1 and 26.2 mmHg. The corrected PET-CO2 bias was -0.6 mmHg, the bias +/- 2SD's was -4.0 and 2.9 mmHg.
Conclusions:
Correcting the PET-CO2 for the degree of hypoxia using the SpO2 in artificially ventilated infants and children with CHD results in a clinically applicable estimation of the PaCO2. As both SpO2 and PET-CO2 can be monitored continuously and non-invasively, this could facilitate artificial ventilation management in children with CHD.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...