Related Experiment Video
Updated: Aug 19, 2026

Surgical Placement of Catheters for Long-term Cardiovascular Exercise Testing in Swine
Published on: February 9, 2016
Serial determination of cardiac output during prolonged work by a CO2-rebreathing technique
Abstract:
Cardiac outputs were calculated on eight male college students while walking on a treadmill at controlled heart rate levels. The heart rate levels were maintained through the use of a heart rate controller (Quinton Model AI-607), standard deviations for heart rate in beats/min ranged from +/-2.1 at the heart rate level 110 to +/-3.2 at 170. Test-retest correlations of the cardiac output values at the various heart rate levels were: at heart rate 110, 0.66 after 7 min and 0.85 at 30 min; at heart rate 150, 0.92 after 7 min and 0.68 at 30 min; at heart rate 130, 0.97 after 7 min, and at heart rate 170, 0.85 after 7 min. The calculated cardiac output values when plotted against oxygen uptake compare favorably with published reports. The data collected demonstrate that the CO2-rebreathing method used in the present investigation provides a reliable bloodless technique for determining multiple cardiac output during prolonged work of varied intensities.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Cardiac Output and Stroke Volume