Modulator design for comprehensive two-dimensional gas chromatography: quantitative analysis of polyaromatic
Tuulia Hyötyläinen1, Minna Kallio, Kari Hartonen
1Tuulia.Hyotylainen@helsinki.fi
Abstract:
A novel cryogenic modulator was constructed for comprehensive two-dimensional gas chromatography (GC x GC). The modulator is based on two-step cryogenic trapping with CO2 and thermal desorption with electric heating. The GC x GC system included a nonpolar first-dimension column and two semipolar second-dimension columns, one connected to a flame ionization detector and the other one to a electron capture detector. A Matlab-based program, which allowed determination of peak heights and volumes, was written for the data analysis. The GC x GC system was applied for the analysis of polyaromatic hydrocarbons and polychlorinated biphenyls. The functioning of the modulator and the quantitativity of the method were studied with both peak volumes and peak heights from a three-dimensional plot. The separate peak areas from the modulated chromatogram were calculated as a comparison. The quantitative results were compared with those obtained with the same system but without the thermal modulation. The method was found to be repeatable and linear with use of peak volumes as well as peak heights. There was also good agreement with the results obtained by integration of separate peak areas. The developed GC x GC method was applied to the analysis of a Soxhlet extract of a certified sediment sample. The results were compared with the certified values.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Elution Process