Related Experiment Video
Updated: Sep 29, 2026

Three-Dimensional Reconstruction for the Whole Lung with Early Multiple Pulmonary Nodules
Published on: October 13, 2023
Comparison of quality of multiplanar reconstructions and direct coronal multidetector CT scans of the lung
Osamu Honda1, Takeshi Johkoh, Shuji Yamamoto
1Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka 565-0871, Japan.
Objective:
The purpose of this study was to compare the quality of coronal multiplanar reconstructions with the quality of direct coronal thin-section multidetector CT (MDCT) scans.
Materials And Methods:
Axial multidetector CT (MDCT) scans were obtained through the entire lung in 10 normal autopsy lung specimens using an MDCT scanner. Four protocols were used: 0.5-mm collimation with a 0.5-mm reconstruction interval; 0.5-mm collimation with a 0.3-mm reconstruction interval; 1-mm collimation with a 0.5-mm reconstruction interval; and 2-mm collimation with a 1-mm reconstruction interval. Multiplanar reconstruction images with 0.5-mm slice thickness were obtained from the four types of data sets. Direct coronal thin-section CT of the same 10 autopsy lung specimens was performed using 0.5-mm scan collimation, a 0.3-mm reconstruction interval, a 25.6-cm field of view, and a 512 x 512 matrix. Two independent observers compared the image quality of each of the four coronal multiplanar reconstruction sets with that of direct coronal thin-section CT scans. The observers analyzed visualization of anatomic features and artifacts.
Results:
The total image quality of the multiplanar reconstructions obtained from 0.5-mm collimation data with or without 0.3-mm overlapping reconstruction was equal to that of direct coronal thin-section CT scans in all 20 interpretations. The image quality of multiplanar reconstruction images from 0.5-mm collimation data either with or without overlapping reconstruction was superior to multiplanar reconstruction images obtained from 1- or 2-mm collimation scans (p < 0.01, Fisher's exact test). Stairstep artifacts in multiplanar reconstructions using 0.5-mm collimation without overlapping reconstruction were equal to those with overlapping reconstruction and were fewer than those on 1- or 2-mm collimation (p < 0.01, Mann-Whitney U test).
Conclusion:
The image quality of coronal multiplanar reconstructions from isotropic voxel data obtained using 0.5-mm collimation, with or without overlapping reconstruction, is similar to that of direct coronal thin-section CT scans.
More Related Videos
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
08:05Lung CT Segmentation to Identify Consolidations and Ground Glass Areas for Quantitative Assesment of SARS-CoV Pneumonia
Published on: December 19, 2020
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...