Relative translucency of six all-ceramic systems. Part I: core materials
Related Experiment Video
Updated: Sep 29, 2026

Additive Manufacturing of Functionally Graded Ceramic Materials by Stereolithography
Published on: January 25, 2019
Michael J Heffernan1, Steven A Aquilino, Ana M Diaz-Arnold
1School of Dentistry and Dows Institute for Dental Research, University of Iowa, Iowa City, Iowa, USA. mheffernan@ureach.com
Statement Of Problem:
All-ceramic restorations have been advocated for superior esthetics. Various materials have been used to improve ceramic core strength, but it is unclear whether they affect the opacity of all-ceramic systems.
Purpose:
This study compared the translucency of 6 all-ceramic system core materials at clinically appropriate thicknesses.
Materials And Methods:
Disc specimens 13 mm in diameter and 0.49 +/- 0.01 mm in thickness were fabricated from the following materials (n = 5 per group): IPS Empress dentin, IPS Empress 2 dentin, In-Ceram Alumina core, In-Ceram Spinell core, In-Ceram Zirconia core, and Procera AllCeram core. Empress and Empress 2 dentin specimens also were fabricated and tested at a thickness of 0.77 +/- 0.02 mm (the manufacturer's recommended core thickness is 0.8 mm). A high-noble metal-ceramic alloy (Porc. 52 SF) served as the control, and Vitadur Alpha opaque dentin was used as a standard. Sample reflectance (ratio of the intensity of reflected light to that of the incident light) was measured with an integrating sphere attached to a spectrophotometer across the visible spectrum (380 to 700 nm); 0-degree illumination and diffuse viewing geometry were used. Contrast ratios were calculated from the luminous reflectance (Y) of the specimens with a black (Yb) and a white (Yw) backing to give Yb/Yw with CIE illuminant D65 and a 2-degree observer function (0.0 = transparent, 1.0 = opaque). One-way analysis of variance and Tukey's multiple-comparison test were used to analyze the data (P<.05).
Results:
Contrast ratios in order of most translucent to most opaque were as follows: Vitadur Alpha 0.60 +/- 0.03, Empress (0.5 mm) 0.64 +/- 0.01, In-Ceram Spinell 0.67 +/- 0.02, Empress 2 (0.5 mm) 0.68 +/- 0.02, Empress (0.8 mm) 0.72 +/- 0.01, Procera 0.72 +/- 0.01, Empress 2 (0.8 mm) 0.74 +/- 0.01, In-Ceram Alumina 0.87 +/- 0.01, In-Ceram Zirconia 1.00 +/- 0.01, and 52 SF alloy 1.00 +/- 0.00.
Conclusion:
Within the limitations of this study, there was a range of ceramic core translucency at clinically relevant core thicknesses. In order of decreasing translucency, the ranges were Vitadur Alpha dentin (standard) > In-Ceram Spinell > Empress, Procera, Empress 2 > In-Ceram Alumina > In-Ceram Zirconia, 52 SF alloy.
More Related Videos
08:29Multi-material Ceramic-Based Components – Additive Manufacturing of Black-and-white Zirconia Components by Thermoplastic 3D-Printing (CerAM - T3DP)
Published on: January 7, 2019
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Total Internal Reflection Fluorescence Microscopy
Polymer Classification: Crystallinity
Crystalline domains are the regions where polymer chains are aligned in an orderly manner and held together in proximity by intermolecular forces. For example, chains in the crystalline domains of polyethylene and nylon are bound together by van der Waals...
Permeability of Concrete
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh.
Thin-Walled Hollow Shafts
Liquid–Solid Solutions