Hemodynamic evaluation of the penile arterial system in patients with erectile dysfunction using power Doppler imaging
Related Experiment Video
Updated: Sep 15, 2026

Assessment of Vascular Function in Patients With Chronic Kidney Disease
Published on: June 16, 2014
Hideo Sakamoto1, Makoto Shimada, Hideki Yoshida
1Department of Urology, Showa University School of Medicine, Tokyo, Japan.
Objectives:
To assess the hemodynamics of the cavernous arteries (CAs) and helicine arteries (HAs) using power Doppler imaging (PDI) in patients with erectile dysfunction (ED).
Methods:
Forty-two patients with and without a definite vascular component of ED were examined by PDI. The hemodynamic variables of the CAs and HAs were measured after intracavernous injection of 20 microg of prostaglandin E(1) .
Results:
The CAs and HAs were visualized clearly and could be evaluated by PDI after prostaglandin E(1) injection in all patients. The hemodynamic variables of both the CAs and HAs differed between the groups. In the nonvasculogenic group, all 18 patients had normal cavernous arterial flow and achieved a full rigid erection. The mean peak systolic velocity in the HA was 19.5 cm/s on the right and 19.1 cm/s on the left. In the vasculogenic group, 43% of the 14 patients with normal cavernous arterial flow achieved a full rigid erection and had hemodynamic variables comparable to those in the nonvasculogenic group, but 57% failed to achieve a full rigid erection and their mean peak systolic velocity in the HA (8.5 cm/s, P = 0.0065 on the right; and 7.0 cm/s, P = 0.0024 on the left) was lower than in the nonvasculogenic group. Ten patients had reduced cavernous arterial flow and a full rigid erection could not be achieved. The mean peak systolic velocity (7.8 cm/s, P = 0.0009 on the right; and 6.5 cm/s, P = 0.0004 on the left) was lower than in the nonvasculogenic group.
Conclusions:
PDI is useful for evaluating the hemodynamics of the penile arterial system in patients with ED. Our data suggest that abnormalities of the HA contribute to ED.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse
The pulse serves as a clinical indicator...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation