Related Experiment Video
Updated: Sep 26, 2026

Laboratory-determined Phosphorus Flux from Lake Sediments as a Measure of Internal Phosphorus Loading
Published on: March 6, 2014
Hanced biological phosphorus removal in membrane bioreactors
1Institut für Verfahrenstechnik TU Berlin. Christian.adam@ivtfg1.tu-berlin.de
Abstract:
Enhanced biological phosphorus removal (Bio-P) in a membrane bioreactor (MBR) promises several advantages but was never attempted as not compatible with high sludge ages. This article includes description and results of bench-scale investigations on Bio-P removal in an MBR. An MBR bench-scale plant (210 L) was operated in parallel to a conventional WWTP under comparable process conditions. The results show that Bio-P removal is possible in MBR. The effluent qualities of the plants were comparable. The effluent P-concentration was always lower than 0.2 mg P(T)/L. In the MBR bench-scale plant P-uptake occurred mainly in the anoxic zone. Investigations with P-spiking showed higher Bio-P potential as P-removal increased up to 20-25 mg/L while P/TS rose up to >6%.
More Related Videos
Related Concept Videos
Phosphoinositides and PIPs
Different phosphoinositides are synthesized and recruited on the cytosolic face of the plasma membrane. The localization of specific phosphoinositides concentrated in separate membrane...
Microbial Bioremediation of Uranium
Microbial Wastewater Treatment
Bioreactor Design and Operational System
Bioplastics
Biological Treatment of Effluent and Waste Water