Clinical evaluation of the Keeler Pulsair 3000 non-contact tonometer
Wendy Lawson-Kopp1, Amy DeJong, Lorne Yudcovitch
1Pacific University, College of Optometry, Forest Grove, Oregon 97116, USA.
Background:
The Keeler Pulsair 3000 is a recently introduced non-contact tonometer that is especially useful for children and those for whom sitting at a slit-lamp or table-mounted unit would be difficult. In this project, intraocular pressures (IOPs) measured by Keeler Pulsair 3000 and Goldmann tonometers were compared to assess validity and reliability of the Pulsair 3000 data.
Methods:
Two Pulsair 3000 IOPs (each the mean of four individual air-puff readings) and two Goldmann IOPs were measured for each eye of 113 subjects. Subjects were also asked which measurement technique they preferred.
Results:
IOPs ranged from 9 to 28 mmHg. Correlations between the two Goldmann IOPs measured for the right and left eyes were 0.98 and 0.97, respectively. These values are higher than correlations between Pulsair and Goldmann measurements (0.86 to 0.91). Pulsair 3000 IOPs were slightly above Goldmann values for pressures of less than 15 mmHg and slightly below for IOPs greater than 15 mmHg. Extrapolation to a Goldmann IOP of 30 mmHg suggests the Pulsair 3000 would read about 6% (1.7 mmHg) too low at this IOP. Eight eyes (7%) had differences between Pulsair 3000 and Goldmann IOP readings of 5.0 mmHg or more. Single outlier pressures accounted for these differences in three out of the eight eyes.
Conclusions:
In the range of 10 to 24 mmHg, the Pulsair 3000 tonometer produced IOP readings that corresponded well with Goldmann values for most eyes and was preferred by the majority of subjects who indicated a preference. The Pulsair 3000 is relatively easy to use by technicians and has numerous special applications in optometric practice (e.g. measuring IOPs for pediatric patients and those with compromised corneas).
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: