Related Experiment Video
Updated: Sep 29, 2026

Fetal Echocardiography and Pulsed-wave Doppler Ultrasound in a Rabbit Model of Intrauterine Growth Restriction
Published on: June 29, 2013
Doppler velocimetry for predicting outcome of pregnancies with decreased fetal movements
Przemyslaw Korszun1, Mariusz Dubiel, Marek Kudla
1Department of Perinatology and Gynecology, University School of Medical Sciences, Poznan, Poland.
Aim:
The aim of this study was to evaluate umbilical artery (UA) and uterine artery (Ut.A) Doppler velocimetry in a low-risk pregnancy group with decreased fetal movements.
Material And Methods:
Eight hundred and eighty-eight women were examined because of decreased fetal movements. All fetuses were alive on maternal admission. In all cases, UA and Ut.A Doppler velocimetries were performed, as well as a nonstress test (NST). The managing clinician was informed only of the UA Doppler.
Results:
In the group of 135 women who gave birth within 2 days, UA velocimetry was abnormal in seven fetuses. In 11 cases, Ut.A vascular resistance was abnormal and in 18 cases 'notch' was stated. There were 19 emergency sections in this group. Signs of increased placental vascular resistance were correlated with need for operational delivery because of fetal distress. Among the remaining 753 women who delivered after more than 2 days after examination, UA velocimetry showed abnormality in five fetuses. In 42 cases the Ut.A pulsatility index was abnormal and in 118 cases an early end diastolic 'notch' was present. There was one perinatal death in this group.
Conclusions:
Decreased fetal movement perception by mothers should be taken seriously. Abnormal placental Doppler was an infrequent finding in these low-risk pregnancies. However, adding UA and Ut.A Doppler velocimetries to conventional NST surveillance might be reassuring for managing clinicians.
Related Concept Videos
Doppler Effect - II
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...

