Updated: Jul 25, 2026

AC Electrokinetic Phenomena Generated by Microelectrode Structures
20:38

AC Electrokinetic Phenomena Generated by Microelectrode Structures

Published on: July 28, 2008

Electrokinetic injection techniques in microfluidic chips.

L M Fu1, R J Yang, G B Lee

  • 1Department of Engineering Science, National Cheng Kung University, Tainan, Taiwan.

Analytical Chemistry
|October 17, 2002
PubMed
Summary

This study introduces a novel multi-T microfluidic injection system. This versatile design integrates multiple conventional configurations, enhancing sample delivery for improved separation efficiency.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Test of CP Symmetry in the Neutral Decays of Λ via J/ψ→ΛΛ[over ¯].

Physical review letters·2026
Same author

[Progress in basic research on hydrogel-based drug delivery systems for the treatment of peri-implantitis].

Zhonghua kou qiang yi xue za zhi = Zhonghua kouqiang yixue zazhi = Chinese journal of stomatology·2026
Same author

Precise Measurement of the Chromoelectric Dipole Moment of the Charm Quark.

Physical review letters·2026
Same author

Precise Measurement of Matter-Antimatter Asymmetry with Entangled Hyperon-Antihyperon Pairs.

Physical review letters·2026
Same author

Observation of Λ[over ¯]p→K^{+}π^{+}π^{-}π^{0} and Λ[over ¯]p→K^{+}π^{+}π^{-}2π^{0}.

Physical review letters·2026
Same author

First Measurement of the D_{s}^{+}→K^{0}μ^{+}ν_{μ} Decay.

Physical review letters·2026

Area of Science:

  • Microfluidics
  • Analytical Chemistry
  • Biotechnology

Background:

  • Microfluidic chip separation efficiency is highly dependent on flow field conditions in the injection microchannel.
  • Understanding the fluid dynamics within the injection microchannel is crucial for optimizing microfluidic system design and operation.

Purpose of the Study:

  • To design and test various microfluidic injection system configurations, including cross, double-T, and triple-T.
  • To introduce and validate a unique multi-T injection configuration capable of simulating conventional systems.
  • To demonstrate the integration of multiple injection functions onto a single microfluidic chip.

Main Methods:

  • Design and fabrication of microfluidic chips with cross, double-T, triple-T, and multi-T injection configurations.

More Related Videos

High Throughput Microfluidic Rapid and Low Cost Prototyping Packaging Methods
07:51

High Throughput Microfluidic Rapid and Low Cost Prototyping Packaging Methods

Published on: December 23, 2013

Picoinjection of Microfluidic Drops Without Metal Electrodes
09:20

Picoinjection of Microfluidic Drops Without Metal Electrodes

Published on: April 18, 2014

Related Experiment Videos

Last Updated: Jul 25, 2026

AC Electrokinetic Phenomena Generated by Microelectrode Structures
20:38

AC Electrokinetic Phenomena Generated by Microelectrode Structures

Published on: July 28, 2008

High Throughput Microfluidic Rapid and Low Cost Prototyping Packaging Methods
07:51

High Throughput Microfluidic Rapid and Low Cost Prototyping Packaging Methods

Published on: December 23, 2013

Picoinjection of Microfluidic Drops Without Metal Electrodes
09:20

Picoinjection of Microfluidic Drops Without Metal Electrodes

Published on: April 18, 2014

  • Utilizing precisely controlled electric field manipulation to act as a virtual valve for sample injection.
  • Experimental testing and comparison of the performance of different injection configurations.
  • Main Results:

    • The multi-T injection configuration successfully simulated the functions of cross, double-T, and triple-T systems.
    • Appropriate manipulation of electric fields within the multi-T configuration enabled versatile sample delivery.
    • The proposed design integrates multiple conventional injection systems into a single, efficient microfluidic chip.

    Conclusions:

    • The novel multi-T microfluidic injection system offers a versatile and integrated solution for sample delivery.
    • This design simplifies microfluidic systems by consolidating multiple injection functionalities.
    • The ability to simulate various injection configurations enhances the flexibility and applicability of microfluidic devices.