Hand exposure in nuclear medicine workers
W Chruscielewski1, J Olszewski, J Jankowski
1Department of Radiological Protection, Nofer Institute of Occupational Medicine, Lodz, Poland. chruwoj@imp.lodz.pl
Abstract:
As a result of the gamma radiation emitted by radioactive elements (e.g. 99mTc and 131I) used in nuclear medicine laboratories for diagnostic and therapeutic purposes, nuclear medicine workers are exposed to whole-body doses. These doses arc usually measured by using individual film dosemeters. Lead or lead glass shields used during the handling of radioisotopes minimise the whole-body doses received. Nevertheless, part of the job has to be performed manually, hence the hands are more exposed to radiation. This paper presents the results of measuring the equivalent dose to the hands of workers employed in five selected nuclear medicine laboratories where technetium and iodine radioisotopes are in common use. Sixty workers, including physicians, nurses, radiopharmacists and technicians, were included in the study. Doses were measured at 1 month intervals. The study indicated that, in some instances, the danger of radiation dose to the hand may be significant. Monthly doses exceeded 50 mSv, which may suggest that an annual dose may be higher than 500 mSv.
More Related Videos
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
08:23An Automated Microscopic Scoring Method for the γ-H2AX Foci Assay in Human Peripheral Blood Lymphocytes
Published on: December 25, 2021
Related Concept Videos
Biological Effects of Radiation
Hand hygiene
Hand washing...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...