Related Experiment Video
Updated: Feb 14, 2026

Formation of Covalent DNA Adducts by Enzymatically Activated Carcinogens and Drugs In Vitro and Their Determination by 32P-postlabeling
Published on: March 20, 2018
Formation and fate of ion pairs during MALDI analysis: anion adduct generation as an indicative tool to determine
1Institute for Pharmaceutical Chemistry, Biocenter, J.-W. Goethe University Frankfurt, Germany.
Abstract:
Stimulated by recent experiments, which verified the preservation of the analyte solution charge state upon incorporation in the host matrix crystals, investigations are reported focusing on the role of analyte and counter ions in the matrix-assisted laser desorption/ionization (MALDI) process. These counter ions are only visible in the MALDI mass spectra under certain conditions, i.e., if inter-ionic proton transfer followed by evaporation of the neutrals is prevented, as in the case of metal cations. However, ion pairs can also survive the MALDI process if anions of very low gas phase basicities are used. By this means the intermediates of ion production in MALDI can be visualized. Depending on the amount of energy transfer to the analyte, which is mainly controlled by the matrix, different grades of adduct generation are observed. The analyte-, matrix- and polarity-dependant adduct distribution substantiates the hypothesis that multi-ion pairs are incorporated in the MALDI crystals and that ionization is essentially accomplished by charge separation processes. Moreover, the adduct distribution--and most probably also the charge separation efficiency--was found to be caused mainly by competition of different anionic species for coordination at the positively charged analyte sites. Furthermore, the results point to a less efficient charge separation with increasing number of ion pairs, which might be one major reason that mainly singly charged ions are obtained with MALDI.
More Related Videos
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
07:49Matrix-assisted Laser Desorption/Ionization Time of Flight MALDI-TOF Mass Spectrometric Analysis of Intact Proteins Larger than 100 kDa
Published on: September 9, 2013
Related Concept Videos
Matrix-Assisted Laser Desorption Ionization (MALDI)
Formation of Complex Ions
Ionization Energy
Indicators
Pore Transport and Ion-Pair Transport
Pore transport, also known as convective transport, is a process where small molecules like urea, water, and sugars rapidly cross cell membranes as though there were channels or pores in the membrane. Although direct microscopic evidence is limited but the concept of pores or channels is widely accepted based on physiological evidence. Despite the lack of direct...
Ions as Acids and Bases
Salts are ionic compounds composed of cations and anions, either of which may be capable of undergoing an acid or base ionization reaction with water. Aqueous salt solutions, therefore, may be acidic, basic, or neutral, depending on the relative acid-base strengths of the salt’s constituent ions. For example, dissolving the ammonium chloride in water results in its dissociation, as described by the equation: