Improving the recoveries of unstable N-chloramines determined by liquid chromatography-postcolumn electrochemical
Mary Bedner1, William A MacCrehan, George R Helz
1Department of Chemistry and Biochemistry, University of Maryland, College Park 20742, USA.
Abstract:
Liquid chromatographic (LC) measurement of individual N-chloramines, which are key byproducts of wastewater and drinking water chlorination, could lead to more effective control of water disinfection. Such measurements are challenging because of analyte instability. A detector selective for N-chloramines is constructed based on postcolumn derivatization with iodide followed by reductive detection of the iodine product at a glassy carbon electrode. In flow injection (FIA) mode, the detector gives identical responses for a test set of four chemically diverse N-chloramines. In the LC mode, losses of the test compounds are observed when LC and FIA responses are compared and quantitated by introducing a relative response factor (RRF). Using the RRF, N-chloramine recoveries are evaluated as a function of multiple LC separation parameters. The highest recoveries are obtained using a reversed-phase (C18) column with an acetonitrile mobile phase and a pH 7.02 aqueous phosphate buffer. With these conditions, linear calibration curves are obtained for all test N-chloramines. The detection limits obtained are in the low 10(-7)-mol/L range, which is nearly tenfold better than previously reported and 10-1000-fold lower than total residual chlorine concentrations typically found in disinfected water and wastewater.
More Related Videos
04:17Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Principles Of Column Chromatography
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors