Related Experiment Video
Updated: Sep 28, 2026

Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
Effects of transmural pressure on brachial artery mean blood velocity dynamics in humans
Mary E J Lott1, Michael D Herr, Lawrence I Sinoway
1Division of Cardiology, Pennsylvania State University College of Medicine, Milton S. Hershey Medical Center, Hershey, Pennsylvania 17033, USA.
Abstract:
The effects of changes in transmural pressure on brachial artery mean blood velocity (MBV) were examined in humans. Transmural pressure was altered by using a specially designed pressure tank that raised or lowered forearm pressure by 50 mmHg within 0.2 s. Brachial MBV was measured with Doppler directly above the site of forearm pressure change. Pressure changes were evoked during resting conditions and after a 5-s handgrip contraction at 25% maximal voluntary contraction. The handgrip protocol selected was sufficiently vigorous to limit flow and sufficiently brief to prevent autonomic engagement. Changes in transmural pressure evoked directionally similar changes in MBV within 2 s. This was followed by large and rapid adjustments [-2.14 +/- 0.24 cm/s (vasoconstriction) during negative pressure and +2.14 +/- 0.45 cm/s (vasodilatation) during positive pressure]. These adjustments served to return MBV to resting levels. This regulatory influence remained operative after 5-s static handgrip contractions. Of note, changes in transmural pressure were capable of altering the timing of the peak MBV response (5 +/- 0, 2 +/- 0, 6 +/- 1 s ambient, negative, and positive pressure, respectively) as well as the speed of MBV adjustment (-2.03 +/- 0.18, -2.48 +/- 0.15, -0.84 +/- 0.19 cm x s(-1) x s(-1) ambient, negative, and positive pressure, respectively) after handgrip contractions. Vascular responses, seen with changes in transmural pressure, provide evidence that the myogenic response is normally operative in the limb circulation of humans.
More Related Videos
09:40Ultrasound Assessment of Flow-Mediated Dilation of the Brachial and Superficial Femoral Arteries in Rats
Published on: November 3, 2016
06:04Pulse-Wave Velocity, Flow-Mediated Dilation, and Carotid Intima-Media Thickness to Assess Cardiovascular Risk in Population with Metabolic Syndrome
Published on: September 27, 2024
Related Concept Videos
Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Pulse
The pulse serves as a clinical indicator...