Related Experiment Video
Updated: Sep 28, 2026

Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
Staging of non-small-cell lung cancer and application of FDG-PET. A cost modeling approach
Paul Verboom1, G Judith M Herder, Otto S Hoekstra
1Institute for Medical Technology Assessment, Erasmus University Rotterdam.
Background:
The presence of (distant) metastases affects the therapy (operation) and prognosis of patients with non-small-cell lung cancer (NSCLC). Fifty percent of the operations are futile due to the presence of a locally advanced tumor or distant metastases. Therefore, more accurate preoperative staging is required with respect to the outcomes (reduction of futile operations) and costs. This study examines current staging procedures and assesses possible situations for incorporating positron emission tomography (PET).
Methods:
A retrospective analysis was performed to assess actual clinical practice in the staging procedure of 337 patients with NSCLC in two Dutch hospitals. Consequently, by combining these data of actual clinical practice with a literature review, a model was developed to determine the influence of PET on the staging outcomes and the costs. In this model the accuracy and costs of PET can be varied as well as the extent of substitution of conventional diagnostic tests by PET.
Results:
Practice variation was found between the two hospitals with regard to the setting in which the diagnostic staging took place (hospitalization, outpatient setting) and the extent of the use of mediastinoscopy. This was reflected in the costs and in the number of (futile) operations.
Conclusion:
Hospitalization is the major cost driver in these patients. From a cost viewpoint, the evaluation of PET in a strategy after diagnostic imaging but prior to invasive staging seems most optimal.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET