Related Experiment Video
Updated: Sep 13, 2026

Trabecular Bone Microarchitecture Evaluation in an Osteoporosis Mouse Model
Published on: September 8, 2023
Bone mineral density, ultrasound velocity, and broadband attenuation predict mechanical properties of trabecular bone
J Töyräs1, M T Nieminen, H Kröger
1Department of Applied Physics, University of Kuopio, Kuopio, Finland. juha.toyras@uku.fi
Abstract:
Measurement of areal bone mineral density (BMD(areal)), broadband ultrasound (US) attenuation (BUA), and speed-of-sound (SOS) are widely used ways to perform clinical assessment of bone quality. In this study, bovine (n = 37) and human (n = 32) trabecular bone was investigated in vitro and in vivo to reveal relationships between mechanical properties, mineral density, and US parameters BUA and SOS. To fulfill these aims, clinical US and dual-energy X-ray absorptiometry (DXA) techniques, as well as dynamic and destructive mechanical testing, were utilized. BUA correlated positively and linearly with BMD(areal) only in human calcaneus of low or moderate density (r = 0.849, n = 32, p < 0.01). When calcaneal areas with high BMD(areal) were included in the analysis, however, the in vivo study revealed that the BUA-BMD(areal) relationship could be described by a second-order polynomial fit (r(2) = 0.618, n = 408). In high-density human or bovine bone, the BUA-bone density relationship was negative. In the in vitro assessment, BUA correlated linearly and negatively with volumetric BMD (BMD(vol)) (r = -0.540, n = 29, p < 0.01) and with storage modulus, as measured at 1 Hz (r = -0.505, n = 28, p < 0.01). A weak positive correlation was found between BUA and mechanical loss tangent (r = 0.322, n = 28, p < 0.1). SOS correlated strongly positively with BMD(vol) (r = 0.888, n = 29, p < 0.01), as well with storage modulus (r = 0.649, n = 28, p < 0.01). In contrast, SOS correlated negatively with loss tangent (r = -0.417, n = 28, p < 0.05). When tested dynamically in the frequency range of 0.01-22.7 Hz, bovine trabecular bone was only slightly viscoelastic. In summary, the most accurate parameters for measuring storage modulus and strength of bovine trabecular bone were SOS and BMD(vol), respectively. BUA failed to predict the mechanical properties of high-density trabecular bone. In vivo mapping of the calcaneus revealed the importance of standardized and reproducible localization of the measurement site for the validity of BUA values.
Related Concept Videos
Bone Disorders
Bone deposition is also affected by the levels of sex hormones like estrogen and testosterone that promote osteoblast activity and bone matrix synthesis. When the level of these hormones decreases due to aging, it causes a reduction in bone deposition. As a result, bone resorption by osteoclasts...
Spongy Bone
Spongy bone is more porous, and less dense compared to compact bone. It is composed of concentric lamellae that are arranged irregularly to form the trabecular network. In some bones, the spaces between trabeculae contain red marrow, where...

