Related Experiment Video
Updated: Aug 14, 2026

On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
Stability of a NDIR analyser for CO2 at atmospheric concentration
Michela Sega1, Elena Amico Di Meane, Margherita Plassa
1Istituto di Metrologia Gustavo Colonnetti, Consiglio Nazionale delle Ricerche Strada delle Cacce 73, 10135 Torino. M.Sega@imgc.to.cnr.it
Abstract:
Carbon dioxide monitoring is significant in the environmental field since this gas plays an important role in the greenhouse effect. In order to determine CO2 concentration and to develop simulation models, it is necessary to carry out measurements which are accurate and comparable in time and space, i.e. SI-traceable. Non-dispersive infrared (NDIR) analysers are employed for CO2 measurements, as they are precise and stable. In order to achieve traceability, such instruments have to be characterized and calibrated. At the Istituto di Metrologia "G. Colonnetti"--CNR, a procedure for calibrating NDIR analysers for CO2 at atmospheric level was developed, which enables to calculate a correction for the analyser output. In addition, a complete uncertainty analysis was carried out and a correct traceability chain was established. The goal of the present work is the study of the stability of a NDIR analyser by repeating calibrations during three years and comparing the correction curves obtained to identify a proper re-calibration interval for such analysers. The investigated instrument has good repeatability and reproducibility, hence satisfactory stability during time, as shown by the short-term and long-term compatibility of calibration curves.
More Related Videos
10:22Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
11:38In situ FTIR Spectroscopy as a Tool for Investigation of Gas/Solid Interaction: Water-Enhanced CO2 Adsorption in UiO-66 Metal-Organic Framework
Published on: February 1, 2020
Related Concept Videos
Standard Enthalpy of Formation
The Equilibrium Constant
Calculating the Equilibrium Constant
For example, gaseous nitrogen dioxide forms dinitrogen tetroxide according to this equation:
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Stability of Equilibrium Configuration
A stable equilibrium occurs when a system tends to return to its original position when given a small displacement, and the potential energy is at its minimum. An example of a stable equilibrium is when a cantilever beam is fixed at one end and a weight is attached to the other end. If the weight...