Infrared imaging of laser-induced heating during Raman spectroscopy of pharmaceutical solids
Jonas Johansson1, Staffan Pettersson, Lynne S Taylor
1Pharmaceutical and Analytical R&D, AstraZeneca R&D Mölndal, S-431 83, Mölndal, Sweden.
Abstract:
Raman spectroscopy is finding increasing popularity as an analytical technique for the analysis of pharmaceutical powders and solid dosage forms. It is well known that illumination by the high intensity lasers used in Raman spectrometers can result in sample heating, however, the extent of the problem has not been assessed for pharmaceutically relevant materials. Using direct thermal imaging of compressed powders, the extent of heating for microcrystalline cellulose (MCC), vanillin, ibuprofen and stearic acid was measured as a function of laser intensity. MCC was found to be the most susceptible to sample heating while ibuprofen was least sensitive. At high laser powers (1.5 W), samples were heated by between 38 and 60 degrees C while at more moderate laser powers (0.7 W) the degree of heating was between 20 and 30 degrees C. The kinetics of the heating process were mathematically modeled for MCC and the derived constants were used to predict the rotation speed necessary to prevent a solid state transition in a heat sensitive compound, theophylline monohydrate. Experimental measurements at different rotation speeds verified that the estimated rotation speed reduced sample heating by the desired amount. In conclusion, the extent of heating is clearly of some concern for pharmaceutical materials but can be substantially reduced by sample rotation.
More Related Videos
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
IR Spectrometers
IR Frequency Region: Fingerprint Region
The...
Applications of IR Spectroscopy: Overview