White-coat effect in normotension and hypertension
Nikos A Zakopoulos1, Vasilios T Kotsis, Vassiliki Ch Pitiriga
1Department of Clinical Therapeutics, Alexandra Hospital, National and Kapoestrial University of Athens, Greece. kotsisva@hol.gr
Blood Pressure Monitoring
|November 1, 2002
Summary
The white-coat effect, the difference between clinic and daytime blood pressure, inversely correlates with ambulatory blood pressure. This effect is most pronounced at lower levels and reverses at very high blood pressure readings.
Area of Science:
- Cardiology
- Hypertension Research
- Diagnostic Monitoring
Background:
- The white-coat effect is defined as the difference between clinic and daytime ambulatory blood pressure measurements.
- Understanding the white-coat effect's behavior across different blood pressure ranges is crucial for accurate hypertension diagnosis.
- Its association with cardiovascular structural changes like left ventricular mass requires further investigation.
Purpose of the Study:
- To investigate the magnitude of the white-coat effect in relation to varying daytime ambulatory blood pressure levels.
- To examine the association between the white-coat effect and left ventricular mass.
- To identify blood pressure thresholds where the white-coat effect changes significantly.
Main Methods:
- 1581 subjects underwent clinic blood pressure readings, 24-h ambulatory blood pressure monitoring, and echocardiography.
- Daytime systolic and diastolic blood pressure levels ranged from 88.0–208.9 mmHg and 40.3–133.0 mmHg, respectively.
- Statistical analyses were performed to correlate white-coat effect with ambulatory blood pressure and left ventricular mass.
Main Results:
- A significant inverse correlation was observed between the white-coat effect and daytime ambulatory blood pressure (systolic r = -0.22, diastolic r = -0.50).
- Left ventricular mass correlated with ambulatory blood pressure but not with clinic blood pressure or the white-coat effect.
- The white-coat effect reversed at high daytime ambulatory blood pressure levels (systolic > 170 mmHg or diastolic > 100 mmHg).
Conclusions:
- The white-coat effect demonstrates an inverse relationship with daytime ambulatory blood pressure.
- It is most prominent at daytime ambulatory blood pressure levels below 140/80 mmHg.
- The effect is reversed at levels exceeding 170/100 mmHg, indicating a potential shift in measurement dynamics at higher pressures.