Indoor air quality in daycare facilities is often poor, with high carbon dioxide (CO2) levels exceeding standards. Elevated CO2 during nap times, especially in isolated rooms, poses health risks to children.
Area of Science:
- Environmental Health
- Pediatric Health
- Building Science
Background:
- Poor indoor air quality (IAQ) in daycare settings is linked to increased upper-respiratory infections in children.
- Elevated carbon dioxide (CO2) exposure can have detrimental health effects, including risks to infants.
Purpose of the Study:
- To assess indoor air quality (IAQ) parameters, specifically CO2, temperature, and humidity, in Midwestern U.S. daycare facilities.
- To identify factors contributing to elevated CO2 levels, particularly during nap times.
Main Methods:
- Continuous monitoring of CO2, temperature, and relative humidity for eight hours in 26 randomly selected daycare facilities.
- Calibration of direct-reading instruments before each measurement to ensure accuracy.
- Statistical analysis, including stepwise multiple regression, to identify predictors of nap-time CO2 levels.
Main Results:
- Over 50% of facilities exceeded the ASHRAE standard for average CO2 levels (1,000 ppm).
- Temperature and relative humidity were outside recommended comfort zones in 42.3% and 15.4% of facilities, respectively.
- Nap-time CO2 levels were significantly higher than non-nap-time levels, particularly in sleeping-only rooms (p < .05).
Conclusions:
- Existing IAQ in many daycare facilities does not meet established standards.
- Nap-time environments require specific attention to mitigate increased CO2 concentrations.
- Recommendations include establishing specific IAQ standards for daycares and avoiding isolated nap-time rooms.
Abstract:
Poor indoor air quality (IAQ) in daycare facilities affects both attending children and care providers. Incident rates of upper-respiratory-tract infections have been reported to be higher in children who attend daycare. Excessive carbon dioxide (CO2) exposure can cause several health effects and even sudden infant death. For this study, 26 facilities were randomly selected in a Midwestern county of the United States. CO2, room temperature, and relative humidity were used as indicators for IAQ and comfort levels. These IAQ parameters were continuously monitored for eight hours at each facility by a direct-reading instrument that was calibrated before each measurement. More than 50 percent of the facilities had an average CO2 level over the American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) standard of 1,000 parts per million (ppm). For temperature and relative humidity, respectively, 42.3 percent and 15.4 percent of facilities were outside of the ASHRAE-recommended comfort zones. The nap-time average CO2 level was about 117 ppm higher than the non-nap-time level. The increment of the nap-time CO2 level in the sleeping-only room over the level in multipurpose rooms was statistically significant (p < .05). According to stepwise multiple regression analysis, nap-time CO2 level was predicted by CO2 level before occupancy, nap-time average temperature, carbon monoxide, and child density (R2 = .83). It is recommended that an appropriate IAQ standard for daycare facilities be established and that children should not be placed in a completely isolated room during nap time.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.