Excretion of FDG into saliva and its significance for PET imaging
A Stahl1, B Dzewas, M Schwaiger
1Department of Nuclear Medicine, Technische Universität München, Germany. a.stahl@lrz.tum.de
Aim:
Assessment of the salivary excretion of FDG and its significance during PET imaging.
Methods:
Salivary samples from 16 patients were obtained during the first three hours after FDG injection and their activity concentrations were measured. Furthermore, regional FDG accumulations in whole body PET scans (60 min p.i., ROI technique) were determined in the following locations: vestibulum oris, floor of the mouth, hypopharynx, parotid gland, submandibular gland. This ROI analysis was repeated after drinking water (0.2 l) and a second scan (120 min p.i.).
Results:
The salivary FDG concentrations (SUV) at the first, second and third hour p.i. were 0.2 +/- 0.1, 0.4 +/- 0.2, and 0.3 +/- 0.2, respectively. The FDG uptake in the investigated cranial and cervical sites ranged from SUV 1.2 +/- 0.5 in the major salivary glands to 2.1 +/- 0.5 in the floor of the mouth. These values remained unchanged after drinking of water.
Conclusion:
The salivary FDG concentration is higher than expected from the low physiologic content of glucose. This may--similarly to renal excretion--reflect a different behavior of FDG and glucose during reabsorption processes. Nevertheless, the salivary concentration of FDG is so low that no relevant influence on PET imaging is to be expected. Accordingly, the drinking of water prior to the scan is of no benefit for FDG PET imaging of the head and the neck.
More Related Videos
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET