Related Experiment Video
Updated: Aug 15, 2026

Quantification of Proteins Using Peptide Immunoaffinity Enrichment Coupled with Mass Spectrometry
Published on: July 31, 2011
Molecular scanner experiment with human plasma: improving protein identification by using intensity distributions of
Markus Müller1, Robin Gras, Pierre-Alain Binz
1Swiss Institute of Bioinformatics, Geneva, Switzerland. markus.mueller@isb-sib.ch
Abstract:
The development of high throughput utilities to identify proteins is a major challenge in present research in the field of proteomics. One such utility, the molecular scanner, uses proteins separated by two-dimensional polyacrylamide gel electrophoresis that are digested in the gel and during transfer onto a collecting membrane. After adding a matrix, the membrane is inserted into a matrix-assisted laser desorption/ionization-time of flight mass spectrometer and a peptide mass fingerprint (PMF) is measured for every scanned site. Since the spacing between scanned sites is much smaller than the size of the most abundant protein spots, there is a certain redundancy in the data that was used in an earlier experiment with Escherichia coli [1] to improve mass calibration and PMF identification results. It was observed that the signal intensity of a peptide mass as a function of the position on the membrane showed similar patterns if peptides stemmed from the same protein. Taking account of these similarities a clustering algorithm was used to find lists of experimental masses with similar intensity distributions, which provided clearer identification of the corresponding proteins. Here, these methods are applied to a human plasma scan, where proteins were highly modified and less separated. The presence of very abundant proteins like albumin and immunoglobulins added another difficulty. The calibration of the initial PMFs was not satisfactory and masses had to be recalibrated. After discarding chemical noise, the membrane was partitioned into regions and for each region protein identification was carried out separately. A new scoring method was used, where the PMF score was multiplied by a factor that measures the similarity of matching peptides. This method proved to be more robust than the method developed in [1] if the region where a protein was found had an extended, nonspherical shape and strong overlap with regions of other proteins. Many proteins annotated on the SWISS-2D PAGE human plasma master gel could be clearly identified and many interesting properties were observed.
More Related Videos
Related Concept Videos
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Proteomics
Proteomics is the study of proteomes' function. It involves the large-scale systematic study of the proteome to denote the protein complement expressed by a genome. Scientist Mark Wilkins coined the term proteomics...