X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Comparative evaluation of JPEG and JPEG2000 compression in quantitative digital subtraction radiography
1University of Ljubljana, Faculty of Medicine, Department of Restorative Dentistry and Endodontics, Ljubljana, Slovenia. ales.fidler@mf.uni-lj.si
JPEG2000 compression is suitable for quantitative digital subtraction radiography (DSR) at a 1:7 compression ratio, performing similarly to JPEG. Higher JPEG2000 compression ratios introduce unacceptable image distortions for DSR analysis.
Area of Science:
- Radiology
- Medical Imaging
- Image Compression
Background:
- Quantitative digital subtraction radiography (DSR) is crucial for assessing bone changes.
- Image compression is necessary for efficient storage and transmission of DSR data.
- Evaluating the impact of different compression standards on DSR accuracy is essential.
Purpose of the Study:
- To compare JPEG and JPEG2000 compression effects on quantitative DSR.
- To determine acceptable JPEG2000 compression ratios (CR) for DSR.
Main Methods:
- In vitro study using pig mandible sections.
- Images acquired at 'Baseline', 'No change', and 'Gain' (simulated bone chips).
- Images compressed using JPEG and JPEG2000 at CRs 1:7, 1:16, 1:22, 1:31; distortion assessed via pixel error and PSNR.
Main Results:
- JPEG showed less distortion at low CRs; JPEG2000 superior at higher CRs.
- No significant difference between JPEG and JPEG2000 at CR 1:7.
- JPEG2000 better for 'no change' measurements at higher CRs, but bone gain volumes were underestimated.
- JPEG overestimated bone gain volumes.
Conclusions:
- JPEG and JPEG2000 perform similarly at CR 1:7 for DSR, provided images are registered before compression.
- JPEG2000 is superior to JPEG at higher CRs but introduces distortions too high for reliable quantitative DSR.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies II: Ultrasonography
Imaging Studies III: Computed Tomography