High-speed characterization and analysis of orange oils with tandem-column stop-flow GC and time-of-flight MS
Tincuta Veriotti1, Richard Sacks
1Department of Chemistry, University of Michigan, Ann Arbor 48109, USA.
Abstract:
High-speed GC with time-of-flight (TOF) MS detection is used for the characterization and analysis of oils rendered from the peel of five diverse species of orange including bergemot orange, bitter orange, tangerine, mandarin orange, and sweet orange. With a user-defined signal-to-noise threshold of 100, 44 peaks were found and 36 compounds identified in the various oils. Some major constituent components show large concentration ranges over the five species. A 14-m-long, 0. 18-mm-i.d. column ensemble consisting of 7.0-m lengths of a trifluoropropylmethyl polysiloxane and a 5% phenyl dimethyl polysiloxane column was temperature-programmed at 50 degrees C/min starting at the time of injection to achieve analysis times under 140 s. The TOFMS was operated with a spectral acquisition rate of 25 spectra/s, and automated peak finding software successfully found all of the components, with the exception of one severely overlapping peak pair in bitter-orange oil. Of the 44 peaks, 25 were identified by use of a TOFMS library created for this study; another 11 were identified with a commercial terpene library, and 8 were not identified. A quantitative comparison (percent of total peak area) is presented for 16 components, which comprise 98.8-99.5% of the total peak area for the five orange species. Stop-flow operation of the column ensemble is used to enhance selectivity for targeted component pairs to facilitate single-channel detection for QA/ QC analysis of characterized samples and to enhance column selectivity for TOFMS characterization in cases in which peak overlap is so severe that only a single peak is observed.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Tandem Mass Spectrometry
