Abstract:
The purpose of this study is to determine whether gas chromatography (GC)-atomic emission detection (AED) can be used in a low-resolution mode for rapid, accurate determinations of total sulfur in fuels at trace levels to complement other popular methods of total sulfur analysis. A method for the rapid determination of total sulfur in fuels (called "fast GC-AED") is developed. The method is tested on gasoline, jet fuel, kerosene, and diesel fuel with sulfur concentrations ranging from 125 mg/L down to 2.5 mg/L. Fast GC-AED shows better performance than traditional GC-AED for total sulfur determinations, especially for complex mixtures containing many different sulfur-containing compounds at trace levels. This method also shows that GC-AED can be used for both rapid determinations of total sulfur and traditional determinations of speciated sulfur without requiring equipment changes. Fast GC-AED is competitive with other popular methods for sulfur analysis. The 5-min program that is developed for fast GC-AED is comparable with the time scale of other methods, such as wavelength dispersive X-ray fluorescence and UV-fluorescence (2 to 5 min). Fast GC-AED also compares favorably with UV-fluorescence for trace sulfur determinations, demonstrating accuracy down to 2.5-mg/L sulfur.
More Related Videos
07:24Combustion Chemistry of Fuels: Quantitative Speciation Data Obtained from an Atmospheric High-temperature Flow Reactor with Coupled Molecular-beam Mass Spectrometer
Published on: February 19, 2018
08:22Nitrogen Compound Characterization in Fuels by Multidimensional Gas Chromatography
Published on: May 15, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...