Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
A new noninvasive measurement system for wave intensity: evaluation of carotid arterial wave intensity and
Kiyomi Niki1, Motoaki Sugawara, Dehua Chang
1Department of Cardiovascular Sciences, The Heart Institute of Japan, Tokyo Women's Medical University School of Medicine, 8-1 Kawada-cho, Shinjuku-ku, Tokyo 162-8666, Japan. mniki@nora.hij.twmu.ac.jp
Abstract:
Wave intensity (WI) is a new hemodynamic index that provides information about the dynamic behavior of the heart and the vascular system and their interaction. Carotid arterial wave intensity in normal subjects has two positive peaks. The first peak, W(1), occurs during early systole, the magnitude of which increases with increases in cardiac contractility. The second peak, W(2), which occurs towards the end of ejection, is related to the ability of the left ventricle to actively stop aortic blood flow. Between the two positive peaks, a negative area, NA, is often observed, which signifies reflections from the cerebral circulation. The time interval between the R-wave of ECG and the first peak (R - W(1)) corresponds to the pre-ejection period, and that between the first and second peaks (W(1) - W(2)) corresponds to ejection time. We developed a new ultrasonic on-line system for obtaining WI and arterial stiffness (beta). The purpose of this study was (1) to report normal values of various indices derived from WI and beta measured with this system, and (2) to evaluate the intraobserver and interobserver reproducibility of the measurements. The measurement system is composed of a computer, a WI unit, and an ultrasonic machine. The WI unit gives the instantaneous change in diameter of the artery and the instantaneous mean blood velocity through the sampling gate. Using these parameters and blood pressure measured with a cuff-type manometer, the computer gives WI and beta. We applied this method to the carotid artery in 135 normal subjects. The mean values of W(1), W(2), NA, R - W(1), and W(1) - W(2) were 8 940 +/- 3 790 mmHg m/s(3), 1 840 +/- 880 mmHg m/s(3), 27 +/- 13 mmHg m/s(2), 104 +/- 14 ms, and 270 +/- 19 ms, respectively. These values did not show a significant correlation with age. The mean value of beta was 10.4 +/- 4.8 and the values significantly correlated with age (men: r = 0.66, P < 0.0001; women: r= 0.81, P < 0.0001). The reproducibility was evaluated by intraobserver intrasession (IA), intraobserver intersession (IE), and interobserver intrasession variability (IO). The reproducibility of R - W(1) and W(1) - W(2) was high: the mean coefficient of variation (mCV) of IA was less than 3%; 95% confidence limits from the mean values (CL) were less than 8% for IE and less than 4% for IO. The reproducibility of W(1) and beta was good: mCV for IA was less than 10%; CL for IE and IO were less than 17%. W(2) and NA showed a higher variability than other indices: mCV for IA was less than 13%, and CL for IE and IO were less than 36%. However, two sessions by the same observer and two sessions by different observers were not biased. Wave intensity measurements with this system are clinically acceptable.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: