Related Experiment Video
Updated: Aug 17, 2026

Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Eluotropic strength in non-aqueous liquid chromatography with porous graphitic carbon
Karen Gaudin1, Pierre Chaminade, Arlette Baillet
1Groupe de Chimie Analytique de Paris-Sud, Laboratoire de Chimie Analytique, Faculté de Pharmacie, Châtenay-Malabry, France. karen.gaudin@cep.u-psud.fr
Abstract:
Porous graphitic carbon is an attractive packing for the chromatographic analysis of highly hydrocarbonaceous compounds with non-aqueous mobile phase. An eluotropic-strength scale of 10 pure organic solvents was established using the methylene selectivity from the fatty acid methyl ester homologous series (chain length between 18 and 31 carbon atoms). Eight binary mobile phases combining a weak solvent: methanol or acetonitrile with a strong solvent: toluene, chloroform, dichloromethane or tetrahydrofuran at different volume fractions phi of strong solvents (ranging from 0.3 to 1.0) were tested and their eluotropic strengths were then compared with those of pure solvents. The curves of the eluotropic strength versus the volume fraction of the strong solvent followed two different trends: linear or curved. The knowledge of the pure solvent strength is not sufficient to predict the eluotropic strength of solvent in the mixture. Then modelling of the eluotropic strength for binary mobile phases was envisaged in order to provide a prediction tool. This model was assessed for the establishment of the composition of eight iso-eluotropic mobile phases. Good assessment was found except in the case of toluene with acetonitrile where the difference between the predicted and the real value was the highest.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
13:36Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Ion-Exchange Chromatography