The long Bain breathing system: an investigation into the implications of remote ventilation
C J Sweeting1, P W Thomas, D J Sanders
1Royal Devon and Exeter Hospital, Exeter, UK.
Abstract:
A long version of the Bain breathing system is commonly used when remote anaesthesia is required, such as during magnetic resonance imaging or radiotherapy. We compared the static compliance and distal pressures over a range of flows in a 1.6 and 9.6 m Bain system. We examined the effect on ventilation of increasing the length of the Bain system in lung models for 10, 20 and 70 kg patients. We found that static compliance was increased in the long Bain system. We found that with matched peak inspiratory ventilator pressures there was a reduction in peak inspiratory pressures at the patient end with the longer system (p < 0.001). A reduction in tidal volume was found with the 9.6 m Bain (p < 0.001), and positive end-expiratory pressure was increased (p = 0.01). Although the effect on tidal volume was proportionally small in the 70 kg simulation (660 and 617 ml in 1.6 and 9.6 m systems, respectively) it increases in significance in children, with a 23% reduction in tidal volume in the 10 kg mock lung (95 and 73 ml in 1.6 and 9.6 m systems, respectively). Anaesthetists should be aware of the reduction in tidal volume and increased positive end-expiratory pressure. During remote anaesthesia with a long Bain system, the ventilator should be adjusted to compensate.
More Related Videos
06:57Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
09:50Real-World M3-BREATHE: Toward Multimodal Mobile Monitoring of Behaviour, Respiration, and Exposures for Treatment and Health Evaluation
Published on: June 5, 2026
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)