Related Experiment Video
Updated: Sep 28, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Investigations with FDG-PET scanning in prostate cancer show limited value for clinical practice
Eeva Salminen1, Annette Hogg, David Binns
1Department of Oncology, Turku University Hospital, Finland. eevsal@utu.fi
Abstract:
The aim of this study was to investigate FDG-PET (fluorodeoxyglucose positron emission tomography) imaging in the management of prostate cancer. Twenty-two patients were studied during different disease phases of prostate cancer, for staging or restaging to clarify specific clinical questions. FDG-PET was performed encompassing the thorax, abdomen and pelvis using the Penn PET 300H scanner. Scanning was begun 60 min after 18F fluorodeoxyglucose marker. Patients were catheterized and administered diuretics to minimize urinary activity. Information obtained with FDG-PET was concordant with findings from other investigations in 7/22 (32%) patients, discordant in 15/22 (68%) patients and equivalent in one patient (4%). PET indicated progressive disease in five patients with prostate-specific antigen (PSA) < 4 ng/L. The impact on management of the patients was high in 46% of cases, low in 41% and for 14% there was no impact on management. The accuracy of FDG-PET was 72% (95% CI 50-89) as confirmed by invasive diagnostics/follow-up. FDG-PET can provide useful information and improve the clinician's decision on further management procedures in selected patients with low PSA and bone or lymph node changes. A negative PET scan in prostate cancer should be interpreted with caution.
More Related Videos
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
08:55A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...